Lumen is designed for a homelab: one hub, a handful of agents on LXC / VMs / bare metal, traffic over your home network. Two failure modes are routine:

  • Hub restarts — kernel patches, config edits, accidental reboot.
  • Network blips — Wi-Fi roam, VLAN reload, switch reboot.

Out of the box the agent + hub absorb both without operator intervention. This page documents how, and the two knobs that control it.

Agent offline buffer

Every agent has a small bbolt file (single-file embedded key/value store, like SQLite-but-simpler) that holds ingest frames the hub hasn’t acknowledged yet. The flow:

tick → collect envelope
├─ POST /api/ingest → 204 No Content
│ └─ on success: drain up to 10 buffered frames
└─ POST /api/ingest → connection refused / 5xx
└─ on failure: enqueue this frame; next tick tries again

The buffer is bounded by age (default 24h) and count (default ~17 280 = 24h × 12/min). Hit either ceiling and the oldest frames are dropped on the next prune. Long outages → some data loss; short ones → zero loss.

Configuration

Env varDefaultWhat it does
LUMEN_AGENT_BUFFER_PATH./lumen-agent-buffer.dbWhere the bbolt file lives. Docker compose overrides to /data/buffer.db (persistent volume); the systemd installer points it at /var/lib/lumen-agent/buffer.db.
LUMEN_AGENT_BUFFER_MAX_AGE24hFrames older than this are pruned even if unsent. Avoids replaying stale data onto a chart when the hub comes back after a multi-day outage.
LUMEN_AGENT_BUFFER_DRAIN10Max frames to ship per successful tick. Higher = faster catch-up, lower = gentler on a recovering hub.

Operational signals

In agent logs you’ll see:

INFO agent starting buffer_path=/data/buffer.db buffer_max_age=24h0m0s
INFO buffer carries forward frames from previous run queued=42
WARN ingest failed — frame buffered err="dial tcp: ... refused" buffer_size=43
INFO buffer drained shipped=10 still_queued=33 drain_err=<nil>

The WARN lines are loud because they mean an outage is in progress — but they’re harmless: the agent will catch up automatically. If they persist for >24h the buffer starts shedding old frames.

Corruption recovery

If the bbolt file is mangled by a power-loss or disk fault, the agent detects it at open time, renames the file aside with a .corrupt-<unix-timestamp> suffix, and starts a fresh one. You lose the buffered backlog but the agent keeps shipping live frames — far better than crash-looping on a stuck file.

Hub batch flush

The hub receives every ingest into an in-memory store (hot path — WebSocket subscribers see the new value within milliseconds) and also queues it for SQLite persistence. The persistence path is batched, not synchronous:

ingest → store.Put (live) ← hot path, sub-ms
→ batcher.Add (queue) ← non-blocking, returns immediately
every 60s OR every 5000 rows
BEGIN; INSERT * N; COMMIT (one fsync)

Why batch

SQLite in WAL mode with synchronous=NORMAL still fsyncs the WAL on every COMMIT. On a 200-host fleet at 5s tick that’s 40 fsyncs per second, plus seek penalty on a spinning disk. Coalescing into one transaction every 60s drops that to one fsync per minute regardless of fleet size — the entire batch fits in a single sequential write to the WAL.

The trade-off is up to one flush interval of data lost on a hub crash. The agent-side buffer (above) replays it on reconnect, so the practical failure mode is “delayed write, not lost write.”

Configuration

Env varDefaultWhat it does
LUMEN_HUB_BATCH_FLUSH_EVERY60sHow often the in-memory queue is flushed to SQLite. Drop to 5s for development (immediate visibility in lumen.db); raise to 5m for very large fleets on slow disks.
LUMEN_HUB_BATCH_FLUSH_SIZE5000Flush early once pending rows hit this, regardless of the interval. Caps memory at fleet scale; flush size × ~120 bytes is the rough RAM ceiling.

Operational signals

In hub logs (LUMEN_HUB_DEV=true for Debug visibility):

INFO batcher starting flush_interval=1m0s flush_size=5000 queue_size=10000
DEBUG batch flushed rows=240 reason=interval took=12ms
DEBUG batch flushed rows=5000 reason=size took=68ms
WARN batcher dropped snapshots due to full queue dropped_since_last_flush=17
INFO batcher stopped

The WARN line only fires if ingest pressure exceeds the queue size between flushes. At default settings (10k queue, 60s flush) that’s ~167 hosts/s sustained — well beyond what a homelab will produce. If you see it, either raise LUMEN_HUB_BATCH_FLUSH_SIZE (smaller flushes, faster turnover) or shorten LUMEN_HUB_BATCH_FLUSH_EVERY.

On graceful shutdown the batcher performs a final flush, bounded by the same 10s deadline as the HTTP server. A SIGKILL skips this.

WS subscribe protocol

The hub broadcasts host snapshots over /api/stream every LUMEN_HUB_STREAM_INTERVAL (default 5s). Clients may optionally send a control frame to narrow what they receive:

// firehose (default if no message ever sent)
{}
// filter to a specific host
{"type":"subscribe","hosts":["webA"]}
// revert to firehose
{"type":"subscribe","hosts":["*"]}

The host detail page uses this to ignore the 99% of WS traffic that isn’t about the host it’s showing. The dashboard view continues to use the firehose default; nothing breaks for older web builds that never send a subscribe frame.

This is per-connection state — no shared registry, no resubscribe on reconnect needed (the next browser navigation re-opens the WS and sends a fresh subscribe).